iBR AUTO CALIBRATION- SEADOO -2017-2023 yaers
NOTICE iBR auto-calibration must be per-formed with the complete reverse gate as-sembly properly installed. Performing theauto-calibration procedure without the reversegate assembly in place will damage the actu-ator. Perform after repairing or removing the jetpump and/or iBR system components.
Connect the vehicle to the BRP diagnostic soft-ware (BUDS2).
- Connect diagnostic
So that your VEHICLE does not fall asleep. I RECOMMEND Connect Power Interface (BRP p/n 515177223 + p/n 529035997).
2. Open BUDS2 and scan VEHICLE
3. TAB–Functions
4 -TAB–Move iBR Up/Down -CLICK
6- TAB -Avto Calibration IBR – CLICK
NOTICE Make sure the iBR actuator is un-locked before pressing the Auto Calibrationbutton.
Follow the informations displayed on the screenso start the AUTO-CALIBRATION sequence